Review on:
Analytical method development and validation
Laxmi S. Vasave*,
Prajakta G. Chavan, Sakshi K. Chaudhari,
Sunila A. Patil, Sunil P. Pawar
Department of Quality Assurance, P. S. G. V. P. Mandal’s College of
Pharmacy, Shahada.
Abstract:
The development
of good analytical method is of highest importance during the process of
drug discovery, launch to market, and development, which results in a
marketing authorization. The objective of this study is to assess the
technique development, standardization, and validation for the drug from
the early phases of formulation establishment through its first batch for
commercial sale. Development of a method for the required element in
process testing, a sample, or the final product to simplify the process of
developing pharmaceuticals and to offer useful methods for assessing the
selectivity, specificity, limits of detection and quantification,
linearity, range accuracy, precision, and stability of the recovery
solution. Also liquid chromatography offers durability and ruggedness of
procedures to allow regular, in-process, and stability evaluation.
Keywords:
Validation, Method Development, Detection,
Quantification, Stability etc.
|
Corresponding Author:
Laxmi S. Vasave
Email ID:
laxmivasave22@gmail.com
|
Article History
Received: 01/07/2023
Accepted: 25/07/2023 Published: 01/09/2023
|
INTRODUCTION:
The reliability of an analytical finding
is an issue of excellent importance to force the formulation scientist in the
developmental stage and impurity profile in stability study, and dissolution
statistics of the steadiness study as well as routine analysis. For routine
analysis and stability analysis, generating reliable and reproducible data is
of the utmost importance. This is particularly true in the context of best
control and validation, which have recently gained more significance in
analytical studies of impurity profile and dissolution. In order to reach
agreement on the proportion of validation studies and on the acceptability
criteria for validation parameters of analytical techniques, this topic should
be seriously studied on a worldwide scale.1
Need
of Analytical Method Validation:
To obtain precise results in the
laboratory while analyzing the registration batch and enhanced stability
testing samples, it is important to use well-characterized and well tested
analytical techniques. It is also vital
to point out that each analytical method has unique features that enable
changes from analyte to analyte. In certain circumstances, each analyte may
additionally require the advancement of unique validation criteria. Also, the
study's ultimate goal can be used to support the approach's appropriateness.
When pattern analysis for a given study is conducted at more than one site and
industrial batch for human consumption, it's important to validate the
analytical method(s) in accordance with ICH guidelines and to provide the
correct validation relevant data for unique sites and unique parameters as well
as to establish inter and intra laboratory reliability.2
Analytical
Method Development and Validation:
A specific analytical method is to be
developed for pharmaceutical formulations through the process of analytical
approach improvement, from the stage of in-process to finished product, and
mini validation is to be finished before beginning the analyses of routine
samples, investigation samples, and stability samples.3
TERMINOLOGY
Validation:
It is prevalent that in the path of
ordinary drug product improvement software, a described analytical approach
will pass through many modifications due to the fact composition modifications,
lower energy can be added or percentage of coating material can also trade at
the formula. Because of the modifications the analytical method can be changed
and if changed it brought to be validated so it calls for exceptional degrees
of validation. Two unique levels/forms of technique validations, entire
validation and partial validation or mini, validation, are described and
characterized as follows.4
Complete
validation:
Complete validation is vital before
executing scientific batch or registration batch of drug product. If any change
inside the system or if any impurity located within the balance look at the existing
technique to be changed and validated once more, and the parameters are
specified under for the whole validation.5
Mini
validation:
Mini validations is needed for all the
test techniques like Assay, Related substance, UOD and Blend Uniformity for analyzing
the routine samples earlier starting the entire validation some parameters to
be checked as consistent with ICH Guidelines reputation standards discuss.6
VALIDATION
PARAMETERS:
Linearity:
A linear data must establish throughout
the variety as consistent. By using linear dilution and the % level of each
parameter listed in table: 1, it may be quickly checked on a biological sample.
Regardless of the technique's level at any given time throughout drug
development, the linear range of the method must be established. In order to
investigate linearity and a wider range of concentrations, ICH guidelines
recommend comparing at least 5 concentrations; other approaches must be
justified. By using an appropriate statistical approach, the correlation coefficient,
Y-intercept, regression line slope, and residual sum of squares must be
provided.
The linearity responses are arranged using
successive dilutions of a single inventory answer. Remaining solvent impurity
blends or solvent combinations will be used for related substances. The
implicated height's reaction is displayed against the associated theoretical
focus. Every impurity should be set up for the associated substance technique
relative response factors and relative retention instances with regard to the
active substance. Reaction factors allow the user to avoid using the impurity
material for each evaluation and are helpful in accounting for reaction
variability in the impurity determination. Use the linearity curve method or a
value close to zero to determine the relative response components. It is
necessary to inject 2 and 0.4% of each impurity and energetic compound, and
then determine the relative reaction element from the slope of the linearity
curve or the ratio between the impurity's reaction aspect and the energetic
compound's reaction element.7
Table
1: Terms & Characteristics of analytical
method
|
Sr. No.
|
Terms
|
Characteristic
|
|
1
|
Linearity
|
The
correlation coefficient R was MT 0.998 at 6 levels of drug concentrations
ranging from 0.05-2.0% for drug and all impurities of the drug substance.
|
|
|
Accuracy
|
The
reportable range of linearity is used to analyze relative accuracy. Over the
tested relative potency range, no relative bias trend is seen.
|
|
|
Precision
|
Degree
of Confidence: 95%+ For the intended purpose of the measurement, the interval
for the average intermediate accuracy across levels across the reportable
range (95% CI% geometric coefficient of variation) is not larger than 20%.
|
|
|
i)
Repeatability
|
Repeatability
demonstrates accuracy across a short time span under the same operating
circumstances. Intra-assay precision is another synonym for repeatability.
|
|
|
ii)
Reproducibility
|
Reproducibility
reflects the precision between laboratories (for example, inter-laboratory
studies, which are commonly used to standardise methods).
|
|
|
iii)
Intermediate precision
|
Variations
within laboratories are expressed by intermediate precision. Potential
sources of variability, such as different periods, diverse environmental
conditions, different analysts, and different equipment, should all be
considered.
|
|
|
Specificity
and selectivity
|
Specificity
and selectivity are concepts that define how much other compounds interfere
with the determination of a compound using a certain analytical process.
Other elements in the working environment may include contaminants,
degradation products, related substances, matrix, or other components.
Specificity is often used to define the final condition of measuring analytes
unambiguously. Selectivity is a relative term that refers to how well certain
analyte in mixtures or matrices may be assessed without interference from
other components that behave similarly.
|
Selectivity
(Specificity):
Analytical methods for clinical and
pre-registration batches of pharmaceutical products must show specificity and
involve degradation studies. The technique must be able to quantitatively
separate every known impurity and degradation product, and if any placebo or
blank peaks are identified, they must be adequately separated from impurity
peaks and essential peaks.
In identification tests, the method's
ability to differentiate should be shown by producing positive outcomes for
samples that contain the analyte and negative outcomes for those that do not.
The technique must be capable of identifying between the target analyte and any
other compounds that may also be present and have a similar chemical structure.
For assay/related substance approaches, the
active peak and each impurity should be considerably apart from all
impurity/degrading peaks, placebo peaks, and blank peaks. The US Pharmacopoeia
should be complicated enough to comply with the precision of each impurity peak
and the impurity peak from an important peak. To find potential interferences,
the matrix components of the blank, placebo, and sample should be analyzed
without the active. A sample of the filtered sample diluents should be analyzed
for potential interferences before being compared to the centrifuged sample if
filters are to be used to clarify sample solutions. Studies on forced
degradation should be carried out if the contaminants or degradants are unknown
or unavailable.8 To find and differentiate the possible degradation
products, forced degradation tests of the active pharmaceutical ingredient
(API), placebo, and final product should be carried out using either peak
purity analysis or a mass spectral analysis. Throughout the forced degradation
studies, the API, a placebo, and the final product should all be exposed to
acid, base, peroxide, heat, light conditions, moisture, or water until the
active has been sufficiently degraded.9 For assay, an acceptable
range of degradation may be between 10% and 30%, and for related chemicals, about
10%, depending on the activity being degraded. Excessive degradation of the active
ingredient or recognized impurity should be avoided to prevent the appearance
of secondary degradants. If a placebo material exists, it should be stressed
under the same conditions, for the same length of time, with the same API, and
with the same outcome. It's vital to assess the degraded placebo samples to
make sure that any newly produced degradants are taken away from the target
analyte and impurity peak. A forced degraded sample using a photodiode array
detector for chromophoric chemicals should pass the peak purity and show no
purity flags. The non-chromophoric substance or GC sample that supports the
mass spectral evaluation of the degradation product peak should not show any
detectable variations in the fragmentation pattern from the parent compound for
any known impurity peak.
Precision:
Precision measures how precisely two
measurements that were taken from the same sample under the same conditions at
the same time were in accordance with one another. Repetition, intermediate
precision, and reproducibility are the three types of precision.10
Repeatability:
Repeatability describes the accuracy over
a brief period of time while using the same process variables. Synonymously
known as intra-assay precision. A homogeneous sample or the same sample
generated in a minimum of six replicates using the test concentration of 100%.
Intermediate accuracy Intermediate precision reflects differences within the
laboratory, such as various days, various analysts, and various tools. Two
distinct analysts, each preparing six sample preparations according to a
prescribed analytical method, can make up an intermediate precision test. On
various days, the analysts conduct their testing using unique instruments and
analytical columns.10
Reproducibility:
Reproducibility describes a method's
accuracy in the presence of laboratory variance, such as various days,
analysts, and equipment, etc. According to the analytical procedure, a total of
six sample preparations may be made at each testing facility. To ensure
statistical equivalence across diverse testing sites, results are analysed.
Reproducibility is acceptable under the same conditions as intermediate
precision.
Accuracy:
For LOQ11, accuracy should be performed at
a minimum of five concentration levels, with the maximum concentration being
six replicate preparations and the median concentration requiring only three,
in accordance with the test method specified. Alternatively, accuracy can be
performed using a spiked synthetic mixture of product components in accordance
with the acceptance criteria and number sample preparation.
Solution
Stability:
The stability of the solution refers to the
stability of the sample and standard solutions that have been extracted from
the sample or matrix and are ready to be injected, and it should be stored
properly at room temperature or in a refrigerator depending on the stability of
the sample and standard solutions. If the solution was frozen before analysis,
it should be thawed to room temperature before determining the stability of the
standard and sample solution. The standard and sample solutions should be made
and analysed at least twice using the recommended procedure. Depending on the
nature of the product, the analysed solutions must be stored in the proper
conditions and their stability can either be established for two days or on an
hourly basis.11
Ruggedness
(Robustness):
Measures an analytical method
potential to be unaffected by a little but deliberate change in technique
and indicates how dependable it will be under normal conditions. Robustness
must now include full validation rather than only micro or preclinical level
validation. It must also include the establishment of the method and attractiveness
requirements before switching the analytical approach to other laboratories.12
Limit
of quantification and detection (LOD and LOQ):
The LOQ is the lowest concentration of an
analyte in a sample that can be accurately and precisely quantified. The
determination of LOQ can be done in a variety of ways. The LOQ parameter is
intended specifically for contaminants, degradation products, and/or residual
solvents when detecting samples at low levels in compounds. The signal to noise
ratio approach and the linearity curve method can be used to determine LOD and
LOQ.13
LOQ based on signal to noise ratio (SIN):
This method can only be used if there is little baseline noise. LOQ can be
determined using computer-aided software or according to US Pharmacopoeia. If
there are no impurities in the test solution or a fabricated mixture of product
components in the placebo preparation, the associated substance and residual
solvents can be spiked with the lowest concentration of impurities. The low
concentration solution yields a signal-to-noise ratio of about 10, which might
be the LOQ, and a signal-to-noise ratio of about 3, which might be the LOD of
the specific impurity. It is important to establish these values for each
contaminant and the targeted peak.
DOCUMENTATION:
Laboratory investigations should be used
to establish and validate the validity of an analytical method, and the
validation report should include proof that these studies were effective. A
validated analytical method must include both general and detailed SOPs as well
as accurate record keeping.
1. Summary information,
2. Method development, degradation study
data and establishment of Relative Retention,
3. Factor, Relative Retention Time and LOQ
etc.
Detail of the certificate of analysis of the
reference standard and/or working standard, validation protocols, summary
reports, analytical method development report, and any micro validation reports
should be included in the summary information. The validity term of the
certificate of analysis reference standard and/or working standard is contained
in a summary table with a list. A protocol number should be assigned to each
and every technique, and the summary report of all validations should be
properly addressed.
a. An
operational description of the analytical method.
b. A
forced degradation stability studies and supporting data.
A description of experiments conducted and
if any error occurs during a validation, the incident report, original and
repeated data detail should be covered.
Documentation of intra and inter-assay
precision and accuracy; If applicable, valid chromatograms or mass spectrograms
with annotations any changes from standard operating procedures, protocols, or
(Good Laboratory Practice) GLPs (if applicable), as well as the explanations
for those deviations, should be noted.13
CONCLUSION:
Statistics for method switching and
analytical method validation play a crucial role in pharmaceutical industry
must generate the information in accordance with relevant medical standards in
order to release the commercial batch and long-term balance information. All
analytical procedures should be thoroughly evaluated and recorded for this
reason as well as the desire to meet regulatory authority requirements. This
article's goal is to provide simple methods with a precise clinical history to
raise the standard of analytical approach creation and validation. This article
provides a notion regarding the quantity of sample coaching, technique, and
attractiveness standards for all metrics used in the validation of analytical
methods. In this text, applications of analytical technique and approach
switching are also taken into account.
These various significant features for
analytical technique improvement and validation have been described, and they
will raise the standard and repute of this field of study.
REFERENCE:
1. Suman
Shrivastava, Pooja Deshpande, S. J. Daharwal, Key Aspects of Analytical Method
Development and Validation, Journal of Ravishankar University–B, 2018, 31 (1),
32-39
2.
Sanjay Bajaj, Dinesh Singla and Neha
Sakhuja, Stability Testing of Pharmaceutical Products, Journal of Applied
Pharmaceutical Science, 2012: 02 (03); 129-138.
3.
G.
Geetha, Karanam Naga Ganika Raju, B. Vignesh Kumar and M. Gnana Raja,
Analytical Method Validation: An Updated Review, IJAPBC – 2012, Vol. 1(1), 64-71.
4.
Elsie Jatto and Augustine O. Okhamafe, An Overview of
Pharmaceutical Validation and Process Controls in Drug Development, Tropical
Journal of Pharmaceutical Research, December 2002; 1 (2): 115-122.
5.
Shivani Sharma, Swapnil Goyal, Kalindi
Chauhan, A Review on Analytical Method Development and Validation, Int J.
App. Pharm., 2018, Vol 10, Issue 6, , 8-15.
6.
Ayesha Nisar Shaikh, Amruta Satish
Sonawane, Muskan Atique Khan, Analytical Method Development and Validation of
Apixaban by RP-HPLC, Journal of Research in Pharmaceutical Science, 2022,
Volume 8, Issue 9 pp: 01-14.
7.
Moosavi, S.
M., & Ghassabian, S. Linearity of Calibration Curves for Analytical
Methods: A Review of Criteria for Assessment of Method Reliability. InTech.
doi: 10.5772/intechopen.72932. (2018).
8.
Nishant Goswami, A validated stability‑indicating
liquid chromatographic method for determination of process related impurities
and degradation behavior of Irbesartan in solid oral dosage, Journal of
Advanced Pharmaceutical Technology & Research, Jan-Mar 2014, Vol 5, Issue
1, Page No. 33-40.
9.
Namdeo G. Shinde, Bhaskar N. Bangar, Sunil
M. Deshmukh, Suyog P. Sulake, Dipak P. Sherekar, Pharmaceutical Forced
Degradation Studies with Regulatory Consideration, Asian J. Res. Pharm. Sci.
2013; Vol. 3: Issue 4, Oct.-Dec. Pg 178-188.
10.
B. Magnusson and U. Örnemark (eds.)
Eurachem Guide: The Fitness for Purpose of Analytical Methods – A Laboratory
Guide to Method Validation and Related Topics, 2nd ed. 2014, Page No. 1-62.
11.
Vaishnavi Jitendra Chaudhari, Sunila A.
Patil, Sunil P. Pawar and Sulbha G. Patil, Analytical method development and
validation: A Review, wjpps, (2022.) Vol 11, Issue 5, Page No. 930-944.
12.
Alfred A. Bartolucci, Karan P. Singh, and
Sejong Bae, Introduction to Statistical Analysis of Laboratory Data,
Introduction to Statistical Analysis of Laboratory Data,First edition, John
Wiley & Sons, Inc, 2016, Page No.
213-234.
13.
Jared L. Anderson, Alain Berthod, Verónica
Pino Estévez, and Apryll M. Stalcup, Analytical Separation Science, First
Edition, Wiley-VCH Verlag GmbH & Co. KGaA, 2015, Page No. 1-52.